Power Quality Solutions

End-to-end power quality management — from harmonic analysis and mitigation to power factor correction, voltage stability, and compliance reporting — integrated with the OpSys monitoring platform.

Poor power quality costs industrial and commercial facilities millions in equipment damage, utility penalties, and production downtime. OpSys delivers hardware solutions and continuous AI-powered monitoring to eliminate these losses.

15–25%
Utility Penalty Savings
Reduction in reactive power charges
2–3×
Equipment Life Extension
Reduced thermal stress from harmonics
3–8%
Energy Loss Reduction
From improved power factor
99.9%
Downtime Prevention
Voltage sag ride-through capability

Solution Portfolio

Four integrated solution areas covering the full spectrum of power quality challenges.

Harmonic Analysis & Mitigation

Comprehensive harmonic measurement, analysis, and mitigation solutions — from passive filters to active power conditioners — ensuring compliance with IEEE 519, IEC 61000-3-6, and grid code requirements.

Continuous THD monitoring up to 50th harmonic order
Passive harmonic filters: 5th, 7th, 11th, 13th tuned filters
Active harmonic filters (AHF) for dynamic compensation up to 50A–600A
12-pulse and 18-pulse transformer solutions for VFD harmonic reduction
IEEE 519 / IEC 61000-3-6 compliance assessment and reporting
Before/after measurement with ROI documentation

Power Factor Correction (PFC)

Automatic power factor correction systems that eliminate reactive power penalties, reduce cable losses, and improve voltage regulation — from fixed capacitor banks to fully automatic APFC panels.

Automatic Power Factor Correction (APFC) panels up to 3000 kVAR
Detuned capacitor banks with reactor protection against harmonics
Static VAR compensators (SVC) for rapid dynamic compensation
STATCOM solutions for utility-grade reactive power management
Real-time PF monitoring with utility penalty avoidance alerts
Integration with OpSys SCADA for fleet-wide PF management

Voltage Quality & Stability

Solutions for voltage sag/swell mitigation, flicker reduction, and voltage unbalance correction — protecting sensitive equipment and ensuring continuous production in industrial and critical infrastructure facilities.

Dynamic Voltage Restorer (DVR) for voltage sag ride-through
Uninterruptible Power Supply (UPS) integration for critical loads
Voltage unbalance correction for three-phase industrial systems
Flicker measurement and mitigation (IEC 61000-4-15 Pst/Plt)
SEMI F47 compliance for semiconductor and data center applications
Real-time voltage quality dashboards with event capture

PQ Monitoring & Compliance Reporting

Class A power quality monitoring instruments and software platform providing continuous measurement, automated compliance reporting, and AI-based trend analysis for proactive power quality management.

IEC 61000-4-30 Class A certified PQ analyzers
EN 50160 / IEEE 1159 automated compliance reports
Long-term trending with anomaly detection and early warning
Multi-site PQ monitoring through OpSys cloud platform
Disturbance recording with waveform capture and analysis
Utility interconnection PQ reports for grid code compliance

Standards Compliance

All solutions designed and tested to international power quality standards.

IEEE 519IEC 61000-3-6EN 50160IEC 61000-4-30SEMI F47IEEE 1159IEC 61000-4-15Grid Code UAE/KSA

Trusted by leading utilities, industrials & EPC contractors across the Middle East

DEWA
DEWA
SEWA
SEWA
ADNOC
ADNOC
Aramco
Saudi Aramco
Masdar
Masdar
ACWA
ACWA Power
GE
Alstom / GE
Siemens
Siemens Energy
Case Studies

Real-World Results

Measurable outcomes from power quality projects delivered across the GCC and beyond.

Harmonic Mitigation — Steel Plant, UAE

Heavy Industry
−86% THD

THD reduced from 28% to 4.2%, eliminating transformer overheating and annual penalty of AED 1.2M.

Solution Applied

18-pulse transformer + 11th/13th passive filters + Class A PQ monitoring

APFC Upgrade — Desalination Plant, KSA

Utilities
PF 0.72 → 0.99

Power factor improved from 0.72 to 0.99, saving SAR 3.4M annually in reactive power charges.

Solution Applied

2,400 kVAR detuned APFC panel with 7% reactors + SCADA integration

Voltage Sag Ride-Through — Data Center, Dubai

Data Center
0 downtime events

Zero unplanned downtime events in 18 months post-installation; SEMI F47 compliance achieved.

Solution Applied

Dynamic Voltage Restorer (DVR) 500 kVA + real-time PQ event logging

Start with a Free PQ Assessment

Our engineers will analyse your power quality data and identify the highest-ROI improvements for your facility.