OpSys
ProductsEnergy ManagementBESS EMS
Energy Management Layer

Battery Energy Storage
Management System (EMS)

Comprehensive BESS Energy Management System with cell-level BMS integration, AI-optimized dispatch strategies, and full grid code compliance. Supports lithium-ion (NMC, LFP), flow batteries, and hybrid storage configurations.

<100ms
Response Time
99.5%
Round-Trip Efficiency
40%
Peak Reduction
15+
Battery Chemistries
BESS Status — Site Alpha
State of Charge (SOC)72.4%
Active Power
-8.5 MW (Charging)
DC Voltage
820 V
Temperature
28.4°C ✓
SOH
97.2%
Cycles
142 / 6000
Mode
Arbitrage

Dispatch Strategies

Six AI-optimized dispatch strategies for maximum value extraction

Peak Shaving

Reduce peak demand charges by up to 40% through intelligent pre-charging based on load forecasts and time-of-use tariff optimization.

Frequency Regulation

Primary and secondary frequency regulation with <100ms response time. Automatic FFR dispatch based on ROCOF detection.

Energy Arbitrage

Day-ahead and intraday market optimization. Charge during low-price periods, discharge during high-price windows.

Renewable Smoothing

Ramp rate control to smooth solar/wind variability. Configurable ramp rate limits (MW/min) for grid code compliance.

Voltage Support

Reactive power injection/absorption for voltage regulation at the point of connection. Q(U) characteristic support.

Black Start

Island mode formation capability with BESS as grid-forming source. Seamless transition from grid-connected to island mode.

Battery Management System (BMS) Integration

Deep BMS integration for cell-level visibility and protection

Cell-Level Monitoring

  • Individual cell voltage (±1 mV accuracy)
  • Cell temperature (±0.5°C accuracy)
  • State of Charge (SOC) per cell
  • State of Health (SOH) estimation
  • State of Power (SOP) calculation
  • Cycle count and calendar aging

Protection Functions

  • Over/under voltage protection
  • Over-current protection (charge/discharge)
  • Over-temperature protection
  • Short circuit protection (<1ms)
  • Ground fault detection
  • Insulation resistance monitoring

Thermal Management

  • Active cooling/heating control
  • Thermal runaway detection
  • Pre-conditioning for cold weather
  • Thermal gradient monitoring
  • Fire suppression interface
  • Ventilation control integration

Communication & Integration

  • CAN Bus (ISO 15765)
  • Modbus TCP/RTU
  • IEC 61850 MMS/GOOSE
  • MQTT for cloud connectivity
  • REST API for EMS integration
  • OPC-UA for SCADA integration

Maximize Your BESS Investment

AI-optimized dispatch strategies that maximize revenue while protecting battery longevity